Vertical constant temperature oscillator
Vertical thermostatic oscillator is used for cell culture, fermentation, hybridization, biochemistry, enzyme and tissue research with high temperature and oscillation requirements.
It is widely applied in the research fields of chemical industry, pharmacy, food, medical and health, environmental protection, agricultural animal husbandry and so on.
1.When the oscillation experiment is over, it can be automatically converted to the incubator to avoid the trouble of replacing the machine after the oscillation experiment.
2.Large screen LCD, menu operation interface, easy to understand;
3.Screen tempered thermal insulation observation window, that is, clearly observe the state of the sample in the operation of the instrument while having a good thermal insulation effect;
4.The left side of the box is equipped with a diameter 25mm test hole, which can be arranged arbitrarily according to the need of placing the place.
5.The parameters set by the user can be stored automatically in the case of sudden power failure and run the original setting program after power on.
6.Using microcomputer PID to control temperature and oscillation frequency, with timing function.
7.The motor has high starting torque, wide speed regulation, no maintenance, constant speed, low heat dissipation and no carbon brush.
8.It is equipped with a door switch. When the box door is opened, the breeze circulation, heating and shaking machine stop automatically, and there is no temperature overshoot.
9.With door switch, when the box door opens, the breeze circulation, heating and shaker stop automatically, without the disadvantage of temperature overshoot
10.Unique control speed circuit, can ensure that the shaker starts smoothly, accelerates smoothly, and prevents the instrument from damage caused by liquid splashing; independent temperature limit alarm system, after exceeding the limit temperature automatically cut off heating, to ensure safe operation without accidents.
11.Automatic control of the speed of the circulating fan can avoid the sample evaporation caused by the excessive speed of the circulating fan in the test process.
Mode |
ZSZ-L150 |
ZSZ-L151 |
ZSZ-L300 |
ZSZ-L301 |
ZSZ-L600 |
ZSZ-L601 |
ZSZ-L6001 |
ZSZ-L6011 |
Internal bladder size(mm) |
520×430×680 |
520×430×680 |
790×530×680 |
790×530×680 |
1126×642×850 |
1126×642×850 |
1126×642×850 |
1126×642×850 |
外型尺寸(mm) |
690×730×1378 |
690×730×1378 |
925×835×1378 |
925×835×1378 |
1251×947×1548 |
1251×947×1548 |
1251×947×1548 |
1251×947×1548 |
control mode |
PID programmable microcomputer controller |
|||||||
Convective mode |
Forced convection |
|||||||
Oscillating mode |
Cyclotron oscillation |
Reciprocating oscillation type |
||||||
Temperature control range |
RT+5~60℃ |
4~60℃ |
RT+5~60℃ |
4~60℃ |
RT+5~60℃ |
4~60℃ |
RT+5~60℃ |
4~60℃ |
Temperature resolution accuracy |
0.1℃ |
|||||||
Temperature fluctuation |
≤±0.5℃ |
|||||||
Temperature uniformity |
≤±1℃ |
|||||||
Illuminance range (matching) |
0~12000LUX |
|||||||
Illumination deviation (selection) |
≤±500LUX |
|||||||
Cyclotron frequency range |
30~300r/min |
30~280r/min |
||||||
Cyclotron frequency accuracy |
±1rpm |
|||||||
Oscillating amplitude of rocker plate |
Φ26mm |
Φ35mm |
0~50mm stepless adjustable |
|||||
Timing range |
0~999h |
|||||||
Roll plate size |
496×350 |
496×350 |
734×458 |
734×458 |
970×560 |
970×560 |
970×560 |
970×560 |
Number of shakes |
Two |
|||||||
Power Supply |
AC220V/50Hz |
|||||||
power |
0.6KW |
0.9KW |
0.8KW |
1.1KW |
1.2KW |
1.5KW |
1.2KW |
1.5KW |
volume |
152L |
152L |
284L |
284L |
614L |
614L |
614L |
614L |
Selection |
The mobile phone short message alarm system sends the equipment fault through SMS to the user's mobile phone. |